افتراضي دائرة مؤقت زمني Timer



السلام عليكم



Timer



Circuit diagram


This timer can be set to count a maximum of 60 hours. It also allows an interval to be set. When this interval is reached, a buzzer sounds. The larger part of the circuit is contained in an Intersil Type ICM7217 four-digit CMOS up/down counter and display. Circuit IC3 is the clock that generates a square wave with a period of 1 s. The clock signal is available at pin 3 (Q13). The clock signal may be divided by 60 in IC4 if it is required to time more than 1 hour.

When S6 is closed, the supply is switched on and IC4 is reset via R9 and C5. The position of S4 determines whether minutes or seconds are counted: maximum 59 h 59 min (pos 2) or 59 min 59 sec (pos 1). If, for instance, a total time of 35 min with an interval at 20 min is to he counted, S4 is set to position 1. Thumb wheel switches S7 to S10 are then set he a display reading of 20.00. Briefly pressing S3 stores this setting in the memory of IC1. Then S7 to S10 are set for a display reading of 35.00. During these settings, S1 should be open. Pressing S2 causes the ICM7217C to count down from 35.00. When display reading 18.00 is reached, the buzzer briefly sounds (energized via N3 and N4). The timer may then be stopped by closing S1. When S1 is opened again, the timer restarts the down count to 00.00. When that reading is reached, the buzzer sounds briefly again. Note that at any time during the count down the timer may be stopped by closing S1.

The timer is reset with S5; when that happens, the buzzer sounds briefly and the display reads 00.00. The set count down period of 35 min is, however, retained in the memory until a new period is programmed. The current drawn by the timer, including the displays, is about 100 mA. If a battery supply is used, it is possible to switch off the displays when the timer is counting by adding a switch (with single break contact) between points A and B. This switch enables the display to be read briefly. With the displays switched off, the current drawn is of the order of only 4 mA.

Do not set the thumb wheel switches to readings greater than 59.59, because the timer will then no longer count correctly.




اعلانات

الصورة الرمزية alprince
alprince
:: عضو ذهبي ::
تاريخ التسجيل: May 2005
الدولة: egypt
المشاركات: 708
نشاط [ alprince ]
قوة السمعة:
قديم 05-06-2005, 10:29 PM المشاركة 2   
افتراضي


دائرة جميله وكنا نتمنى ان تترجم الى العربى

اعلانات اضافية ( قم بتسجيل الدخول لاخفائها )

عبد الباسط
:: مهندس ::
تاريخ التسجيل: Jun 2005
المشاركات: 3
نشاط [ عبد الباسط ]
قوة السمعة:
قديم 14-06-2005, 08:59 PM المشاركة 3   
افتراضي


دائرة جميلة فعلا ولكن اتمني ان احصل علي معلومات علي المؤقت 555 وشكرا


togi
:: مهندس ::
تاريخ التسجيل: Jul 2010
المشاركات: 1
نشاط [ togi ]
قوة السمعة:
قديم 24-07-2010, 09:25 PM المشاركة 4   
افتراضي


شكرا اتمنى ان تكون مدعومه بالخارطة


رضوان حلاق
:: مهندس ::
تاريخ التسجيل: Jun 2010
الدولة: سوريا الاسد \ الشام
المشاركات: 39
نشاط [ رضوان حلاق ]
قوة السمعة:
قديم 28-07-2010, 11:14 AM المشاركة 5   
افتراضي


اخي مشكور على جهودك ولكن خلي ببالك انو نحنا عرب
بعدين الصورة لاتظهر

تقبل مروري ونقدي برحابة صدر


ehabshban
:: مهندس ::
تاريخ التسجيل: Dec 2009
المشاركات: 2
نشاط [ ehabshban ]
قوة السمعة:
قديم 20-05-2011, 02:59 PM المشاركة 6   
Post


السلام عليكم



Timer



Circuit diagram


This timer can be set to count a maximum of 60 hours. It also allows an interval to be set. When this interval is reached, a buzzer sounds. The larger part of the circuit is contained in an Intersil Type ICM7217 four-digit CMOS up/down counter and display. Circuit IC3 is the clock that generates a square wave with a period of 1 s. The clock signal is available at pin 3 (Q13). The clock signal may be divided by 60 in IC4 if it is required to time more than 1 hour.

When S6 is closed, the supply is switched on and IC4 is reset via R9 and C5. The position of S4 determines whether minutes or seconds are counted: maximum 59 h 59 min (pos 2) or 59 min 59 sec (pos 1). If, for instance, a total time of 35 min with an interval at 20 min is to he counted, S4 is set to position 1. Thumb wheel switches S7 to S10 are then set he a display reading of 20.00. Briefly pressing S3 stores this setting in the memory of IC1. Then S7 to S10 are set for a display reading of 35.00. During these settings, S1 should be open. Pressing S2 causes the ICM7217C to count down from 35.00. When display reading 18.00 is reached, the buzzer briefly sounds (energized via N3 and N4). The timer may then be stopped by closing S1. When S1 is opened again, the timer restarts the down count to 00.00. When that reading is reached, the buzzer sounds briefly again. Note that at any time during the count down the timer may be stopped by closing S1.

The timer is reset with S5; when that happens, the buzzer sounds briefly and the display reads 00.00. The set count down period of 35 min is, however, retained in the memory until a new period is programmed. The current drawn by the timer, including the displays, is about 100 mA. If a battery supply is used, it is possible to switch off the displays when the timer is counting by adding a switch (with single break contact) between points A and B. This switch enables the display to be read briefly. With the displays switched off, the current drawn is of the order of only 4 mA.

Do not set the thumb wheel switches to readings greater than 59.59, because the timer will then no longer count correctly.



الله يعطيك العافية
وشكراً كتير


سرمد سعيد
:: مهندس ::
تاريخ التسجيل: Sep 2008
المشاركات: 2
نشاط [ سرمد سعيد ]
قوة السمعة:
قديم 22-05-2011, 11:55 AM المشاركة 7   
x4 المؤقت


الله يعطيك العافية
وشكراً كتير

مؤقت



الدائرة الرسم التخطيطي


يمكن تعيين هذا الموقت لحساب مدة أقصاها 60 ساعة. كما يسمح ليتم تعيين فاصل زمني. عندما يتم التوصل إلى هذا الفاصل الزمني ، وهو الجرس الأصوات. ويرد الجزء الأكبر من حلبة في Intersil نوع ICM7217 المكمل أربعة أرقام أعلى / أسفل وعرض العداد. الدائرة IC3 هو الساعة التي تولد موجة مربع مع فترة من 1 س. إشارة ساعة يتوفر في دبوس 3 (Q13). ويمكن تقسيم هذه الإشارة على مدار الساعة بنسبة 60 في IC4 إذا هو مطلوب منها المزيد من الوقت من 1 ساعة.

عند إغلاق S6 ، يتم تبديل العرض على وتتم إعادة تعيين IC4 عبر R9 و C5. موقف S4 يحدد ما إذا كان يتم احتساب دقيقة أو ثانية : الحد الأقصى 59 ساعة 59 دقيقة (نقاط البيع 2) أو 59 دقيقة 59 ثانية (نقاط البيع 1). إذا ، على سبيل المثال ، وهو وقت ما مجموعه 35 دقيقة مع فاصل في 20 دقيقة هو انه يحسب ، يتم تعيين S4 إلى الوضعية 1. يتم تعيين الإبهام عجلة تبديل لS7 - S10 من ثم عرض قراءة 20،00. الضغط لفترة ومخازن العنوان S3 هذا الإعداد في ذاكرة IC1. ثم يتم تعيين S7 - S10 من للقراءة عرض 35،00. خلال هذه الإعدادات ، يجب أن تكون مفتوحة S1. S2 الضغط يؤدي إلى ICM7217C العد التنازلي من 35،00. عندما يتم التوصل إلى عرض 18،00 القراءة ، لفترة وجيزة الجرس الأصوات (N3 عن طريق تنشيط وN4). ثم قد يكون توقف مؤقت عن طريق إغلاق S1. عندما S1 هو فتح مرة أخرى ، إعادة تشغيل جهاز ضبط الوقت العد التنازلي إلى 00.00. عندما يتم التوصل إلى القراءة ، والجرس الأصوات مرة أخرى لفترة وجيزة. لاحظ أنه في أي وقت خلال العد التنازلي الموقت قد تتوقف عن طريق إغلاق S1.

تتم إعادة تعيين جهاز ضبط الوقت مع S5 ، وعندما يحدث ذلك ، الجرس الأصوات لفترة وجيزة وعرض يقرأ 00.00. الفرز المنصوص عليها فترة من 35 دقيقة ، مع ذلك ، تبقى في الذاكرة حتى يتم برمجة فترة جديدة. الحالية التي رسمها الموقت ، بما يعرض ، هو حوالي 100 مللي أمبير. إذا تم استخدام البطارية العرض ، فمن الممكن لإيقاف تشغيل جهاز ضبط الوقت عندما يعرض تعول بإضافة التبديل (مع كسر اتصال واحدة) ما بين نقطة وباء هذا التبديل يمكن أن يقرأ على الشاشة لفترة وجيزة. مع يعرض مغلقا ، الحالية استخلاصه هو من أجل من 4 مللي أمبير فقط.

لا تقم بتعيين مفاتيح عجلة الإبهام إلى قراءات أكبر من 59،59 ، وذلك لأن توقيت وعندئذ لم يعد الاعتماد بشكل صحيح.


مع تحياتي
المهندس


التعديل الأخير تم بواسطة : سرمد سعيد بتاريخ 22-05-2011 الساعة 11:56 AM السبب: اضافة توقيع

أحمد عزت 210
:: مهندس ::
تاريخ التسجيل: May 2011
المشاركات: 5
نشاط [ أحمد عزت 210 ]
قوة السمعة:
قديم 23-05-2011, 04:07 AM المشاركة 8   
افتراضي


مشكوررررررر
بس والله ما فهمت حاجة



الساعة معتمدة بتوقيت جرينتش +3 الساعة الآن: 06:40 AM
موقع القرية الالكترونية غير مسؤول عن أي اتفاق تجاري أو تعاوني بين الأعضاء
فعلى كل شخص تحمل مسئولية نفسه إتجاه مايقوم به من بيع وشراء وإتفاق وأعطاء معلومات موقعه
التعليقات المنشورة لا تعبر عن رأي موقع القرية الالكترونية ولايتحمل الموقع أي مسؤولية قانونية حيال ذلك (ويتحمل كاتبها مسؤولية النشر)